HP StorageWorks P9000 Manual page 254

Remote web console messages
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 62 Error codes (part code 7105) (continued)
Part
Error
Code
Number
7105
8518
7105
8519
7105
8520
7105
8521
7105
8522
7105
8523
7105
8524
7105
8525
7105
8526
7105
8527
7105
8528
7105
8529
7105
8530
7105
8531
7105
8532
7105
8533
7105
8535
7105
8536
7105
8537
7105
8538
254 Message (part code group 7nnn)
Error Message
You cannot create a pair, because the
track format is different for each. Make
sure that the specified emulation type is
the same for both.
You cannot set a pair because the
number of cylinders is different for each.
Make sure that the capacity is the same
for both.
You cannot set a pair, because the
volume type is different for each.
The number of multiple copy jobs
exceeded the maximum.
The emulation type of the S-VOL is not
supported.
The emulation type of the T-VOL is not
supported.
The emulation type is not supported.
An internal logic error occurred.
An internal logic error occurred.
An internal logic error occurred.
An internal logic error occurred.
An internal logic error occurred.
An internal logic error occurred.
An internal logic error occurred.
The command has been rejected,
because the S-VOL or the T-VOL is being
used by the host.
The command has been rejected,
because the emulation type of the
specified volume is not supported or the
specified T-VOL is used as a data volume
of Continuous Access Journal Z.
A processor failure was detected.
A cache failure was detected.
The cache capacities do not match.
An SM failure was detected.
Recommended Action
Check the emulation type.
Check the volume capacity.
Specify the volume with the same
emulation type, and retry the operation.
Check the contents, and retry.
Specify the supported emulation type.
Specify the supported emulation type.
Specify the supported emulation type.
Please contact HP Technical Support.
Please contact HP Technical Support.
Please contact HP Technical Support.
Please contact HP Technical Support.
Please contact HP Technical Support.
Please contact HP Technical Support.
Please contact HP Technical Support.
Stop the usage by the host.
Specify a volume of the supported
emulation type. When the T-VOL is used
as a data volume of Continuous Access
Journal Z, the command cannot be
executed in the current status of
Continuous Access Journal Z pair.
See the section "Sharing Business Copy
Z volumes" in the HP StorageWorks
P9000 Business Copy for Mainframe
Systems User Guide for the relation
between the status of Continuous Access
Journal Z pair and the Business Copy Z
operations.
Please contact HP Technical Support.
Please contact HP Technical Support.
Please contact HP Technical Support.
Please contact HP Technical Support.
Severity
Level
W
W
W
W
W
W
W
E
E
E
E
E
E
E
W
W
E
E
E
E

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp p9500Storageworks p9500

Table of Contents