Table 59 Error codes (part code 7005) (continued)
Part
Error
Error Message
Code
Number
7005
68924
The specified volume is a volume of
using two mirrors, which are included in
3DC cascade, 3DC multi target, or Delta
resync configuration. The operation for
this volume failed due to one of the
following reasons.
The specified volume was used by
Delta resync of Continuous Access
Journal.
The specified volume was used by a
data volume of Continuous Access
Journal.
7005
75002
The command was rejected, because the
Thin Provisioning volume specified as
P-VOL was not associated with a pool.
7005
75003
The command was rejected, because the
Thin Provisioning volume specified as
S-VOL was not associated with a pool.
7005
75004
The command was rejected, because the
Thin Provisioning volume specified as a
reserved volume was not associated with
a pool.
7005
75005
The command was rejected, because no
LU path was set to the volume specified
as P-VOL.
7005
75006
The command was rejected, because no
LU path was set to the volume specified
as S-VOL.
7005
75007
The command was rejected, because no
LU path was set to the volume specified
as a reserved VOL.
7005
78053
The operation failed because the current
microcode version does not support the
capacity of specified P-VOL.
7005
78054
The operation failed because the current
microcode version does not support the
capacity of specified S-VOL.
7005
78055
The operation failed because the current
microcode version does not support the
capacity of specified reserved volume.
Recommended Action
Specify another volume.
Associate the specified Thin Provisioning
volume with a pool, then retry the
operation.
Associate the specified Thin Provisioning
volume with a pool, then retry the
operation.
Associate the specified Thin Provisioning
volume with a pool, then retry the
operation.
Set an LU path to the specified P-VOL,
then retry the operation.
Set an LU path to the specified P-VOL,
then retry the operation.
Set an LU path to the specified P-VOL,
then retry the operation.
Check the microcode version of the
storage system.
Check the microcode version of the
storage system.
Check the microcode version of the
storage system.
Severity
Level
W
W
W
W
W
W
W
W
W
W
Part code 7005 249