HP StorageWorks P9000 Manual page 248

Remote web console messages
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 59 Error codes (part code 7005) (continued)
Part
Error
Code
Number
7005
68837
7005
68838
7005
68839
7005
68867
7005
68868
7005
68869
7005
68922
7005
68923
248 Message (part code group 7nnn)
Error Message
The command has been rejected,
because the specified P-VOL is a volume
of Thin Provisioning whose zero data is
being discarded.
The command has been rejected,
because the specified S-VOL is a volume
of Thin Provisioning whose zero data is
being discarded.
The command has been rejected,
because the specified reserved volume
is a volume of Thin Provisioning whose
zero data is being discarded.
The command has been rejected,
because the volume specified as P-VOL
is a quorum disk.
The command has been rejected,
because the volume specified as S-VOL
is a quorum disk.
The command has been rejected,
because the volume specified as the
reserved volume is a quorum disk.
The specified P-VOL is a volume of using
two mirrors, which are included in 3DC
cascade, 3DC multi target, or Delta
resync configuration. The operation for
this P-VOL failed due to one of the
following reasons.
The specified volume was used by
Delta resync of Continuous Access
Journal.
The specified volume was used by a
data volume of Continuous Access
Journal.
The specified S-VOL is a volume of using
two mirrors, which are included in 3DC
cascade, 3DC multi target, or Delta
resync configuration. The operation for
this S-VOL failed due to one of the
following reasons.
The specified volume was used by
Delta resync of Continuous Access
Journal.
The specified volume was used by a
data volume of Continuous Access
Journal.
Recommended Action
Wait until the process of discarding zero
data is completed, then retry the
operation.
Wait until the process of discarding zero
data is completed, then retry the
operation.
Wait until the process of discarding zero
data is completed, then retry the
operation.
Specify another volume.
Specify another volume.
Specify another volume.
The operation cannot be executed in the
current status of Continuous Access
Journal pair. See the section about the
interoperability with other products and
functions described in the HP
StorageWorks P9000 Business Copy
User Guide for the relation between the
state of Continuous Access Journal pair
and the Business Copy operations.
The operation cannot be executed in the
current status of Continuous Access
Journal pair. See the section about the
interoperability with other products and
functions described in the HP
StorageWorks P9000 Business Copy
User Guide for the relation between the
state of Continuous Access Journal pair
and the Business Copy operations.
Severity
Level
W
W
W
W
W
W
W
W

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp p9500Storageworks p9500

Table of Contents