HP StorageWorks P9000 Manual page 212

Remote web console messages
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 53 Error codes (part code 6505) (continued)
Part
Error
Code
Number
6505
68783
6505
68784
6505
68804
6505
68805
6505
6881 1
6505
68812
6505
68813
6505
68815
6505
68842
212
Message (part code group 6nnn)
Error Message
The Paircreate operation failed because
the specified primary data volume was
used by Continuous Access Synchronous
or External Storage Access Manager.
The Pairresync operation failed because
the specified primary data volume was
one of the following.
The volume was not used by
Continuous Access Synchronous or
External Storage Access Manager.
The volume was used by Continuous
Access Synchronous or External
Storage Access Manager, but the pair
status was not PSUS or PSUE.
The M-VOL cannot be used because
M-VOL is a volume of FICON(R) Data
Migration.
The R-VOL cannot be used because
R-VOL is a volume of FICON(R) Data
Migration or Data Migration.
The specified volume cannot be used as
a journal volume because it is used by
FICON(R) Data Migration.
A pair could not be created because the
specified secondary data volume was a
Thin Provisioning volume whose capacity
was being changed.
A pair could not be created because the
specified primary data volume was a
Thin Provisioning volume whose capacity
was being changed.
The pair cannot be released because the
specified volume is used as the pair
volume of Continuous Access
Synchronous or External Storage Access
Manager.
The operation failed, because the
specified secondary data volume was a
volume of Thin Provisioning whose zero
data was being discarded.
Recommended Action
The specified master journal group runs
on the 2DC configuration in which the
Continuous Access Synchronous or
External Storage Access Manager
cooperates.
Delete the Continuous Access
Synchronous or External Storage Access
Manager pair, and retry the operation,
or specify the volume that is not used by
the Continuous Access Synchronous or
External Storage Access Manager.
The master journal group of the specified
primary data volume runs on the 2DC
configuration in which the Continuous
Access Synchronous or External Storage
Access Manager cooperates.
Delete the Continuous Access
Synchronous or External Storage Access
Manager pair volume or suspend it.
Check the status of the specified M-VOL
from the host or the SVP.
Check the status of the specified R-VOL
from the host or the SVP.
Specify a volume that is not used by
FICON(R) Data Migration.
Check each capacity of the primary data
volume and the secondary data volume
after the capacity change of secondary
data volume ends. Plan a combination
of volumes for pair creating.
Check each capacity of the primary data
volume and the secondary data volume
after the capacity change of primary
data volume ends. Plan a combination
of volumes for pair creating.
The specified volume runs on the 2DC
configuration in which the Continuous
Access Synchronous or External Storage
Access Manager cooperates.
Release the pair of Continuous Access
Synchronous or External Storage Access
Manager, then retry the operation.
Retry the operation after the completion
of discarding zero data on the specified
volume.
Severity
Level
W
W
W
W
W
W
W
W
W

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp p9500Storageworks p9500

Table of Contents