HP StorageWorks P9000 Manual page 211

Remote web console messages
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 53 Error codes (part code 6505) (continued)
Part
Error
Error Message
Code
Number
6505
68025
The specified primary data volume is
used as a pair volume of Continuous
Access Synchronous, External Storage
Access Manager, or Continuous Access
Synchronous Z. The operation failed
because the Disaster Recovery Extended
function was not installed in the primary
storage system.
6505
68026
The specified secondary data volume is
used as a pair volume of Continuous
Access Synchronous, External Storage
Access Manager, or Continuous Access
Synchronous Z. The operation failed
because the Disaster Recovery Extended
function was not installed in the
secondary storage system.
6505
68028
Journals cannot be added to the
extended consistency group(EXCTG),
because the current microcode version
does not support LDKC numbers other
than 0.
6505
68759
The status of the specified volume is
Simplex or SMPL.
Check whether the LDEV number or LUN,
and mirror ID of the specified volume are
correct.
6505
68778
The Add Pair(Paircreate) operation failed
because the specified primary data
volume was a System Disk.
6505
68779
The Add Pair(Paircreate) operation failed
because the specified secondary data
volume was a System Disk.
6505
68780
The specified volume cannot be used as
a journal volume because it is a System
Disk.
6505
68781
The specified operation failed, because
"LU" was specified for the Error Level.
Please specify "Mirror" for the Error
Level, and retry the operation.
6505
68782
The Paircreate operation failed because
"0" was specified for the Mirror ID.
Please specify other than 0 for the Mirror
ID, and retry the operation.
Recommended Action
Install the Disaster Recovery Extended
function in the primary storage system.
Install the Disaster Recovery Extended
function in the secondary storage system.
Confirm the LDKC number of the
specified extended consistency group.
Check whether the LDEV number or LUN,
and mirror ID of the specified volume are
correct.
Check whether the specified primary
data volume is a System Disk.
Check whether the specified primary
data volume is a System Disk.
Check whether the specified primary
data volume is a System Disk.
The specified master journal runs on the
2DC configuration in which the
Continuous Access Synchronous or
External Storage Access Manager
cooperates.
Specify "Mirror" for the Error Level.
The specified master journal group runs
on the 2DC configuration in which the
Continuous Access Synchronous or
External Storage Access Manager
cooperates.
Specify other than "0" for the Mirror ID,
then retry the operation.
Severity
Level
W
W
W
W
W
W
W
W
W
Part code 6505
21 1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp p9500Storageworks p9500