Table 50 Error codes (part code 6005) (continued)
Part
Error
Code
Number
6005
68873
6005
68874
6005
68875
6005
68876
6005
68877
6005
68878
6005
68879
6005
68880
6005
68881
6005
68882
6005
68883
6005
68889
6005
68890
6005
68891
166 Message (part code group 6nnn)
Error Message
The operation failed, because the
specified volume was defined in the LU
path.
The operation failed, because the
emulation type of the specified volume
was not OPEN -V.
The operation failed, because the
specified volume was a LUSE volume.
The operation failed, because the parity
group of the specified external volume
was composed of two or more LDEVs.
The operation failed, because the
specified volume was a reserved
volume of Business Copy.
The operation failed, because the
specified volume was a journal volume.
The operation failed, because the
specified volume was a pool volume.
The operation failed, because the
specified volume was used for Auto
LUN.
The operation failed, because the
specified volume was used as a system
disk.
The operation failed, because the
quorum disk was inaccessible.
The operation failed, because the
specified serial number was different
from the serial number of the quorum
disk.
The operation failed, because the
quorum disk was blocked.
The operation failed, because the
specified serial number was not RCU
but MCU.
The operation failed, because the
following specified parameters did not
match the information in the quorum
disk.
Serial number of MCU
Serial number of RCU
Quorum disk ID
Recommended Action
Specify another volume, or
release the LU path
definition.
Check the emulation type of
the volume.
Select another volume, or
release the LUSE setting.
Select a parity group of an
external volume that is
composed of a single LDEV.
Select another volume, or
release the Business Copy
setting.
Select another volume, or
release the journal volume
setting.
Select another volume, or
release the pool volume
setting.
Select another volume, or
release the Auto LUN setting.
Select another volume.
Check the following
conditions on the external
volume specified for the
quorum disk.
If it is blocked.
If a path is defined.
Check the serial number of
the quorum disk.
Check the status of the
quorum disk.
Specify the serial number of
RCU and retry the operation.
Confirm the serial numbers
of MCU and RCU, and the
quorum disk ID.
Severity Level
W
W
W
E
W
W
E
E
W
W
W
W
W
W