HP StorageWorks P9000 Manual page 163

Remote web console messages
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 50 Error codes (part code 6005) (continued)
Part
Error
Error Message
Code
Number
6005
68012
The operation failed because the
specified R-VOL was used as a Thin
Provisioning volume.
6005
68020
"Maximum Initial Copy Activities (CU)"
cannot be changed to Enable or
Disable, because there are pairs in
COPY or Pending status.
6005
68022
The specified M-VOL is used as a data
volume of Continuous Access Journal
or Continuous Access Journal Z. The
operation failed because Disaster
Recovery Extended function is not
installed in the MCU.
6005
68023
The specified R-VOL is used as a data
volume of Continuous Access Journal
or Continuous Access Journal Z. The
operation failed because Disaster
Recovery Extended function is not
installed in the RCU.
6005
68027
The operation failed because the RCU
does not support the CU number, the
LDKC number or the LU number of the
specified M-VOL.
6005
68757
The Paircreate operation has failed
because the specified S-VOL, which is
a Thin Provisioning volume, is already
used by another program product.
6005
68758
The Add Pair(Paircreate) operation
failed because the specified R-VOL was
a System Disk.
6005
68764
The Add Pair(Paircreate) operation
failed because the specified M-VOL was
a System Disk.
6005
68787
The operation failed because the
Continuous Access Synchronous
function was not installed.
6005
68788
The operation failed because the
External Storage Access Manager
function was not installed.
6005
68789
The Paircreate operation failed because
the Continuous Access Synchronous
function was not installed in the RCU.
6005
68790
The Paircreate operation failed because
the External Storage Access Manager
function was not installed in the RCU.
6005
68791
The operation failed because the
specified volume was not an R-VOL.
Recommended Action
Check whether the specified
R-VOL is a Thin Provisioning
volume.
Confirm that no pairs are in
COPY or Pending status,
then retry the operation.
Install Disaster Recovery
Extended function to the
MCU.
Install Disaster Recovery
Extended function to the
RCU.
Check the CU number, the
LDKC number, or the LU
number of the specified
M-VOL.
Select another volume that
is not used by other program
products such as Business
Copy/Snapshot, and Auto
LUN, or cancel the use of the
volume operated by other
program products, and retry
the operation.
Check whether the specified
R-VOL is a System Disk.
Check whether the specified
R-VOL is a System Disk.
Install the Continuous Access
Synchronous function to the
storage system.
Install the External Storage
Access Manager function to
the storage system.
Install the Continuous Access
Synchronous function to the
RCU.
Install the External Storage
Access Manager function to
the RCU.
Refresh the window, and
confirm whether the
specified volume is an
R-VOL.
Severity Level
W
W
W
W
W
W
W
W
W
W
W
W
W
Part code 6005 163

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp p9500Storageworks p9500

Table of Contents