HP StorageWorks P9000 Manual page 149

Remote web console messages
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 50 Error codes (part code 6005) (continued)
Part
Error
Error Message
Code
Number
6005
8796
The operation failed because the
specified R-VOL applied to any of the
following:
A T-VOL of Business Copy Z or
Compatible FlashCopy.
An S-VOL of Business Copy.
A reserved volume of Business Copy
Z or Business Copy.
A volume of Business Copy Z or
Business Copy in Reverse Copy
status.
A volume of FICON(R) Data
Migration.
6005
8797
If the M-VOL is a Business Copy
Z/Compatible FlashCopy T-VOL, one
S-VOL must be paired with one T-VOL.
If the M-VOL is a Business Copy S-VOL,
one P-VOL must be paired with one
S-VOL.
6005
8798
The MCU is already used for Business
Copy Z/Business Copy/Compatible
FlashCopy.
6005
8799
The M-VOL is already in use for Auto
LUN.
6005
8800
The R-VOL is already in use for Auto
LUN.
6005
8801
The R-VOL is reserved, or the RCU or
the path between MCU-RCU is in a
heavy load condition.
6005
8808
Please retry Add
Pair(Paircreate)/Resume Pair(Pairresync)
operation in a few minutes.
6005
8809
Please wait. Retry Add
Pair(Paircreate)/Resume Pair(Pairresync)
operation in a few minutes.
Recommended Action
Check the status of the
specified R-VOL from the
host or the SVP.
Check the status of the
specified M-VOL from the
host or the SVP.
Confirm the status of
Business Copy Z/Business
Copy/Compatible
FlashCopy in MCU from the
host or the SVP.
Verify the status of the
specified M-VOL.
Verify the status of the
specified R-VOL.
Verify the status of the
specified R-VOL. If the
device is not reserved, retry
the operation.
The add/resume pair
operation failed, because
the either the specified
volume or another volume in
the same group is being
changed to simplex or
suspend status. Retry the
operation after the status
change is completed.
Add/resume pair operation
failed. The specified volume
or another volume in the
same group being changed
to simplex/suspend status in
RCU. After a few minutes,
refresh and check the
Continuous Access
Synchronous window. If
specified volume is in a
permissible status, retry the
operation.
Severity Level
W
W
W
W
W
W
W
W
Part code 6005 149

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp p9500Storageworks p9500

Table of Contents