Table 50 Error codes (part code 6005) (continued)
Part
Error
Error Message
Code
Number
6005
8735
Invalid RCU serial number, SSID, Link
Address or Controller ID.
6005
8736
The specified RCU or SSID contains
some Remote Copy volume pairs.
6005
8737
An internal error occurred.
6005
8738
Remote Copy is not supported under
the MCU Controller emulation type.
6005
8739
NVS status of MCU is not active.
6005
8740
NVS status of RCU is not active.
6005
8741
The logical paths between the MCU
and RCU are not established.
6005
8742
Pinned track(s) exists on the M-VOL.
6005
8743
Pinned track(s) exists on the R-VOL.
Recommended Action
Check the serial number,
SSID and link address of the
RCU, and set the correct
value. Then retry the
operation. If the same error
occurs, please contact HP
Technical Support.
Delete all Remote Copy
volume pairs of the specified
RCU or SSID, and retry the
operation.
Please contact HP Technical
Support.
The emulation type of the
MCU does not support
Continuous Access
Synchronous. If you want to
use Continuous Access
Synchronous, please contact
HP Technical Support.
The MCU NVS status
specified by the host is not
active. Set the NVS to "on"
for the MCU, using any
attached host, then retry the
operation.
The RCU NVS status
specified by the host is not
active. Use any attached
host to set the NVS to "on"
for the MCU, then retry the
operation.
Check the path status
between the MCU and the
RCU.
Check the status of the
M-VOL tracks, and clear the
pinned tracks.
Check the status of the
R-VOL tracks, and clear the
pinned tracks.
Severity Level
W
W
E
W
W
W
W
W
W
Part code 6005 143