HP StorageWorks P9000 Manual page 106

Remote web console messages
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 38 Error codes (part code 3305) (continued)
Part
Error
Code
Number
3305
2005
3305
201 1
3305
2015
3305
2022
3305
2081
3305
2085
3305
2086
3305
2087
3305
2088
3305
2089
3305
2090
3305
2091
3305
2092
3305
2093
3305
2094
106 Message (part code group 3nnn)
Error Message
An error occurred during SVP
processing.
The status of the disk subsystem requires
maintenance (for example, the subsystem
is blocked, the shared memory is
inconsistent, or some other factor).
An error occurred while connecting to
the subsystem. Please wait for a while,
and then retry the operation.
An error occurred during SVP
processing.
An error occurred during a VLL operation
to add or delete customized volumes.
Please wait for a while, and then retry
the operation.
Copying is in progress for Remote Copy,
Business Copy, Business Copy Z,
Snapshot, or Auto LUN pairs.
The configuration of Remote Copy,
Business Copy, Business Copy Z, Auto
LUN, or Snapshot has been defined.
The system is online to the mainframe
host.
The Remote Copy pair is suspended.
The corresponding CHA might contain
the last path between the MCU and RCU
of Remote Copy.
Business Copy, Business Copy Z, or
Snapshot setting exists.
The backup server of Business Copy, or
Business Copy Z, or Snapshot is running.
Some Business Copy, or Business Copy
Z, or Snapshot pairs exist.
Some Business Copy, or Business Copy
Z pairs exist.
Some Business Copy, or Business Copy
Z pairs exist.
Recommended Action
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
A communication error occurs. If the
same error occurs despite retrying,
please contact HP Technical Support.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
To perform a VLL operation on an
external volume, check the status of the
path to the external volume.
Wait a while, then retry the operation.
Release the configuration definition, then
retry the operation.
Take the storage system offline from the
host.
Add an alternative path.
Be sure there is an alternative path from
the MCU.
Release the setting(s) or stop the I/O(s),
then retry the operation.
Stop the backup server, then retry the
operation.
Split them.
Resynchronize them.
Change the status of the volumes to
Simplex.
Severity
Level
E
E
E
E
E
W
W
W
W
W
W
W
W
W
W

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp p9500Storageworks p9500

Table of Contents