fwAlarmsFilterSet

fwAlarmsFilterSet
Enables or disables alarms for Fabric Watch.
Synopsis
fwalarmsfilterset [mode]
Description
Use this command to configure alarm filtering for Fabric Watch. By turning off the alarms, all
nonenvironment class alarms are suppressed. By turning on the alarms, all class alarms are
generated.
Notes
This command requires a Fabric Watch license.
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command
Availability" for details.
Operands
This command has the following operand:
mode
Examples
To enable alarms in Fabric Watch:
See Also
fwAlarmsFilterShow
360
Specify 1 to enable the alarms, 0 to disable the alarms. If no operand is
specified, the default value is 0 (alarms deactivated). This operand is
optional.
switch:admin> fwalarmsfilterset
FW: Alarms are already disabled
switch:admin> fwalarmsfilterset 1
FW: Alarms are already enabled