2
sysMonitor
--apply
--cancel
--show
--config mem | cpu
952
none
Event triggers no action.
-buffer value
Specifies the buffer value for in-range behavior. A buffer defines a zone within
which event criteria are met, rather than a single threshold value. This
operand is optional with the -trigger options and valid only with these options.
-nosave
Prevents the configuration changes from being saved persistently. This option
allows you to make and view changes without overwriting the saved
configuration. When you use --config with the -nosave option and the
switch reboots your changes will be lost.
Applies the custom or default configuration for thresholds, actions, or both.
This command allows you to choose between custom and default settings.
The specified configuration takes effect upon execution of this command.
When you select custom, the saved configuration becomes effective.
Cancels a nonpersistent configurations. This command effectively undoes
the -nosave operation without reboot.
You must always specify a class and area when you apply or cancel a
configuration. Thresholds and alarm levels are optional; if omitted, all
nonpersistent configurations for the specified class and area are used.
Displays the Fabric Watch configuration for the specified class. When used
without operands, this command displays the current Fabric Watch
configuration for all classes and areas. When used with optional arguments,
the output displays partial views or status information.
-current_status
Displays current values for a specified class or area. This operand is optional
and valid only with the --show option. The output includes the class, area,
port number, circuit ID (for the Brocade 7800 and FS8-24 only), Value, and
State. The State field reports whether the current value is above, in range, or
below (info) the configured threshold. If no class or area is specified, this
command displays current values for all Fabric Watch classes and areas (not
only those configured with this command).
The following operands are optional with the --apply, --cancel, and --show
options; if omitted, default thresholds are used.
-action_level def | cust
Configures or displays default or custom action settings.
-thresh_level def | cust
Configures or displays default or custom thresholds.
Configures the parameters for monitoring system CPU or memory usage. The
following parameters are configurable with this command.
-poll
Specifies the polling interval in seconds. Valid values are between 10 and
3600 seconds. The default value is 120 seconds. This operand is optional.
-retry
Specifies the number of retries before Fabric Watch takes action. The default
value is 3.
-limit
Specifies a usage limit as percentage of available resources.