Custom Attributes
Table 15
TABLE 15
Application
Custom
config Index
System Settings
The following system-related parameters are configurable on a Virtual Fabric-aware switch.
TABLE 16
Field
system.blade.bladeFaultOnHwErrMsk
system.cpuLoad
system.blade.bladeFaultOnHwErrMsk
system.cpuLoad
Examples
To enable signature validation for downloading firmware:
See Also
configDefault, configShow, chassisEnable, chassisDisable, configure, ipAddrSet,
portCfgLongDistance, switchDisable, switchEnable, upTime
Fabric OS Command Reference
53-1001764-02
lists custom attributes that may be modified.
Configurable custom attributes
Attribute
Config Index (0 to ignore):
OEM custom configuration. This attribute is for internal use only.
System Settings
If this field is set to a value other than 0, then any nonfatal HW ASIC data
parity error causes the problem blade to be powered off.
Sets a threshold to define internally when the CPU is busy. The default
threshold is 121, which represents a CPU instantaneous load average of 1.21
in the uptime or top command. The range is 10 through 121 (representing
CPU load thresholds of .10 through 1.21).
switch:admin> configurechassis
Configure...
cfgload attributes (yes, y, no, n): [no] \fBy\fR
Enforce secure config Upload/Download (yes, y, no, n): [no]
Enforce signature validation for firmware (yes, y, no, n): [no]
Custom attributes (yes, y, no, n): [no] \fBy\fR
Config Index (0 to ignore): (0..1000) [0]
system attributes (yes, y, no, n): [no] \fBy\fR
system.blade.bladeFaultOnHwErrMsk: (0x0..0xffff) [0x0]
system.cpuLoad: (10..121) [121]
Type
Number
Type
Default
Number
0x0
Number
121
2
configureChassis
Default
Range
0
0-10000
Range
0x0 to 0xffff
10 to 121
143