Brocade Communications Systems 8 Command Reference Manual page 285

Fabric os command reference manual supporting fabric
Hide thumbs Also See for 8:
Table of Contents

Advertisement

-nframes count
-length data_length
-compress mode
Examples
To run the test on slot 2 with PHY loopback sending 10 frames:
Diagnostics
When it detects failures, the test may report one or more of the following error messages:
PATH_TEST_ERR
PATH_TEST_CHIP_INIT_ERR
PATH_TEST_IMAGE_ERR
PATH_TEST_TIMEOUT_ERR
PATH_TEST_HEARTBEAT_ERR
PATH_TEST_INVALID_RESULT
PATH_TEST_GE_PORT_ENABLE_ERR
PATH_TEST_GE_PORT_DISABLE_ERR
See Also
fcipChipTest
Fabric OS Command Reference
53-1001764-02
5
Central ASIC FC loopback
7
SFP and central ASIC FC loopback
8
PHY and central ASIC FC loopback
9
FCIP FPGA GMAC and central ASIC FC loopback
Specifies the number of frames to send. The test progresses until the
specified number of frames are transmitted on each port. The default value is
100 (Brocade 7500/FR4-18i and Brocade 7800/FX8-24).
Specifies the data length of the frames used in the test (Brocade
7500/FR4-18i only). The default is 1,024; the maximum is 2,112 FC frames
and 8,196 data packets.
Specifies the compression device for which to select or to bypass data
compression for the test (Brocade 7500/FR4-18i only). By default, data
compression is used. This setting is applicable only to path mode 1 and 2.
switch:admin> fcippathtest
Running fcippathtest ..............
Test Complete: fcippathtest Pass 10 of 10
Duration 0 hr, 1 min & 50 sec (0:1:50:942).
passed.
slot 2 -path 2 -nframes 10
--
2
fcipPathTest
253