powerOffListSet

Sets the order in which slots are powered off.
Synopsis
powerofflistset
Description
Use this command to Modify the order in which slots are powered off. This command displays the
current order, and then prompts you interactively to confirm or modify the power-off position for
each slot.
Whenever a power supply goes out of service or a field-replaceable unit (FRU) RU is inserted, the
system's available power is compared to the system's required power to determine if there is
enough power to operate. If less than the required power is available, the power-off list is
processed, until there is sufficient power for the system to operate.
If the system's power supply drops abruptly to insufficient levels, the power-off list cannot be
processed. The sudden lack of power causes the CP board processors to cease executing the
firmware.
For example, if only one power supply is available to power a fully loaded system and the power
supply is removed from the chassis, all system operations terminate immediately, and the
power-off list cannot be processed. However, if the system is running on two power supplies (this is
not recommended) and one goes into a predicted fail state (in which the power supply is still
supplying power), the power-off list is processed as described.
The power-off list does not affect the order, in which slots are powered on. On power-on or when an
additional power supply is added, slots are processed sequentially, starting at slot 1.
Notes
CP blade slots are not included in the power-off list.
Command output may vary depending on the hardware platform.
.Some FRUs may use significant power, but cannot be powered off by the software. For example a
missing blower FRU may change the power computation enough to affect how many slot blades can
be powered up.
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command
Availability" for details.
Operands
none
Examples
To modify the power-off list order:
Fabric OS Command Reference
53-1001764-02
switch:admin> powerofflistset
Slot
Current POL
-------------------
10
1st
9
2nd
8
3rd
7
4th
4
5th
3
6th
2
7th
1
8th
1st slot to be powered off: (1..10) [10] 1
2
powerOffListSet
817