the display poe interface power command without any argument, the PoE
power information about all PoE-capable ports on the switch will be displayed.
Example
# Display the power information of the port GigabitEthernet3/1/1.
<SW8800> display poe interface power GigabitEthernet3/1/1
Port power

display poe pse

Syntax
display poe pse
View
Any view
Parameter
None
Description
Use the display poe pse command to display the parameters of all the PoE cards
in the switch that serve as a power sourcing equipment (PSE).
Example
# Display the parameters of all the PoE cards in the switch.
<SW8800> display poe pse
PSE Information of slot 6:
Table 119 Description on the fields of the display poe pse command
Field
Power Current Value
Power Remaining Value Remaining power of the card
Power Max Value
Power Peak Value
Power Average Value
Software Version
Hardware Version
n
The sampling cycle of the current power of the interface card is 1 minute, and the
sampling cycle of the peak power and average power is 5 minutes.

display poe slot

Syntax
display poe slot slotnum
Power Current Value
Power Remaining Value
Power Max Value
Power Peak Value
Power Average Value
Software Version
Hardware Version
CPLD Version
Description
Current power of the card
Maximum power of the card
Peak power of the card
Average power of the card
PSE software version
PSE hardware version
PoE Configuration Commands
:700 mW
:67 W
:738 W
:806 W
:1 W
:0 W
:290
:000
:021
881