up-value: Upper temperature limit, in the range 20 to 90
Description
Use the temperature-limit command to configure temperature limit.
Use the undo temperature-limit command to restore temperature limit to
default value.
Example
# Set the lower and upper temperature limit of card 0.
<SW8800> temperature-limit 0 10 75

update l3plus

Syntax
update l3plus slot slot-no filename file-name ftpserver server-name
username user-name password password [ port port-num ]
View
System view
Parameter
slot-no: Slot for the service processing module to be updated.
file-name: Name of upgrading file to be downloaded. The file suffix is .app.
server-name: IP address or host name of FTP Server where the file to be updated
locates.
user-name: User name for file transfer protocol (FTP) login.
password: User password for FTP login.
port-num: FTP port number, in the range 0 to 65,535. By default, it is 21.
Description
Use the update l3plus command to update service processing modules. After the
command is executed, the system logs into an FTP Server with the host name, user
name and user password provided. The system downloads the host software
containing load program of service processing module to the system's synchronous
dynamic random access memory (SDRAM), and uses the file to enable service
processing modules.
c
CAUTION:
When you use the update l3plus command to update service processing
modules, you must use the switch host APP file which includes the load
program of L3PLUS service processing modules.
The maximum size of L3PLUS update file loaded by the update l3plus
command is 24 M.