51
PoE PSU Supervision
Display Commands
display poe-power
ac-input state
display poe-power
alarm
P
E PSU S
O
Syntax
display poe-power ac-input state
View
Any view
Parameter
None
Description
Use the display poe-power ac-input state command to display the AC input
state of each power supply unit (PSU).
Example
# Display the AC input state of each PSU.
<SW8800> display poe-power ac-input state
PSU 1 AC Input State : Lack Phase
PSU 2 AC Input State : Normal
PSU 3 AC Input State : Lack Phase
Table 120 Description on the fields of the display poe-power ac-input state command
Field
Description
NORMAL
The AC input is normal.
Under Limit
The AC input is below the lower threshold.
Upper Limit
The AC input is above the upper threshold.
Lack Phase
The AC input is lack of phase.
Fuse Broken The fuse is blown.
Switch Off
The switch is off.
Syntax
display poe-power alarm
View
Any view
UPERVISION
C
OMMANDS