By default, no source IP address is configured. The system uses the IP address of
the source interface as the source IP address.
Example
# Set the source IP address of this test to 192.168.60.60.
<SW8800>system-view
System View: return to User View with Ctrl+Z.
[SW8800] nqa-agent enable
[SW8800] nqa administrator icmp
[3Com-administrator-icmp] source-ip 192.168.60.60

test-enable

Syntax
test-enable
undo test-enable
View
NQA test group view
Parameter
None
Description
Use the test-enable command to execute the NQA test.
Use the undo test-enable command to compulsively stop the current NQA test.
n
The test result can not be automatically displayed after the NQA test is
executed. You need to use the display nqa command to display the test result.
When the system is testing, parameters in the test group can not be changed
except the brief description of the operation and the condition of sending Trap
information to the network management system.
Example
# Execute the NQA test.
<SW8800>system-view
System View: return to User View with Ctrl+Z.
[SW8800] nqa-agent enable
[SW8800] nqa administrator icmp
[3Com-administrator-icmp] test-enable

test-failtimes

Syntax
test-failtimes times
undo test-failtimes
View
NQA test group view
NQA Configuration Commands