1034
C
61: S
M
C
HAPTER
YSTEM
AINTENANCE
OMMANDS
View
User view
Parameter
all: Enables or disables all the debugging.
timeout interval: Specifies the interval (in minutes) during which the debugging
all switch is on. The value ranges from 1 to 1440. With this configuration, all
debugging takes the time at which it is enabled as the start time, and takes effect
during the predefined time. And after that, all debugging is disabled.
module-name: Module name.
debugging-option: Debugging option.
Description
Use the debugging command to enable the system debugging.
Use the undo debugging command to disable the system debugging.
By default, all the debugging processes are disabled.
The switch provides various kinds of debugging functions for technical support
personnel and experienced maintenance staff to troubleshoot the network.
Enabling the debugging will generate a large amount of debugging information
and decrease the system efficiency. Specially, network system may collapse after all
the debugging is enabled by the debugging all command. So it is not suggested
to use the debugging all command. It is convenient for the user to disable all the
debugging with undo debugging all command.
Related command: display debugging.
Example
# Enable IP packet debugging.
<SW8800> debugging ip packet
IP packet debugging switch is on.
The above output shows that the IP packet debugging is enabled.
display
Syntax
diagnostic-information

display diagnostic-information

View
Any view
Parameter
None

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

88148810

Table of Contents