By default, Ethernet switches do not output log information to the console.
This command takes effect only after system logging is started.
Related command: info-center enable, display info-center.
Example
# Configure to output log information to the console through channel 0.
<SW8800> system-view
System View: return to User View with Ctrl+Z.
[SW8800] info-center console channel 0

info-center enable

Syntax
info-center enable
undo info-center enable
View
System view
Parameter
None
Description
Use the info-center enable command to enable the system log function.
Use the undo info-center enable command to disable system log function.
By default, system log function is enabled.
Only after the system log function is enabled can the system output the log
information to the info-center loghost and console, and so on.
Related command: info-center loghost, info-center logbuffer, info-center
console channel, info-center monitor channel, display info-center.
Example
# Enable the system log function.
<SW8800> system-view
System View: return to User View with Ctrl+Z.
[SW8800] info-center enable

info-center logbuffer

Syntax
info-center logbuffer [ channel { channel-number | channel-name } | size
buffersize ]*
undo info-center logbuffer [ channel | size ]
View
System view

Hide quick links: