Clock Datetime; Clock Summer-Time - 3Com 8807 Command Reference Manual

8800 series
Hide thumbs Also See for 8807:
Table of Contents

Advertisement

61
Basic System
Configuration and
Management
Commands

clock datetime

clock summer-time

S
M
YSTEM
Syntax
clock datetime HH:MM:SS YYYY/MM/DD
View
User view
Parameter
HH:MM:SS: Current time. HH ranges from 0 to 23. MM and SS range from 0 to
59.
YYYY/MM/DD: Year, month and date. YYYY ranges from 2000 to 2100. MM
ranges from 1 to 12 and DD ranges from 1 to 31.
Description
Use the clock datetime command to configure the current date and clock of the
switch.
By default, the date and clock of the switch is set to 0:0:0, 2000/1/1.
The current date and clock of the switch must be set by this command where
absolute time is strictly required.
Related command: display clock.
Example
# Set the current date of the switch to 0:0:0, 2001/01/01.
<SW8800> clock datetime 0:0:0 2001/01/01