10.10 Positioning Control
Configurator PMX settings
Allocation of I/O signals
Signal name
BUSY
POS
MPOS
Sample program
The execution condition is differential execution.

10.10.5 J-point Control (JOG Positioning)

● When the positioning table start contact or positioning simultaneous start contact turns on,
the pulse output starts. In the J-point control, the unit operates at a taret speed after the
startup, and starts the position control when the J-point control positioning start input (X1, X5
or Y50, Y51) turns on.
● For J-point control, only "Increment" can be used as a control method.
10-54
Application
Control flag
Positioning table start
Positioning
simultaneous start
I/O number
Axis 1
Axis 2
CH0
CH1
X30
X31
Y30
Y31
Axis 3
Axis 4
CH2
CH3
X32
Y32
Y34
WUME-FP7MXY-06
X33
Y33