Operation at the time of deceleration stop (Repeating E-point control)
When the unit detects a deceleration stop, the unit will come to a stop after repeating
positioning control N+2 times. However, the unit will stop the control when reaching the set
repeat count.
■
Operation at the time of deceleration stop (Repeating P-point control, C-point
control)
When the unit detects a deceleration stop, it stops the operation after repeating the positioning
control N+1 times. However, the unit will stop the control when reaching the set repeat count.
● When a system stop is executed, the unit will stop the pulse output immediately without
repetitive operations.
● When an emergency stop is executed, the unit will stop the pulse output after a specified
emergency stop setting time without repetitive operations.
WUME-FP7MXY-06
10.11 Repeat Operation
10-65