3.1 Input/Output Specifications
Item
ON→OFF
Min. input pulse width
Input time constant setting
Output points per common
(Note 1)
The mode of input voltage is selected by software. The default is the 5-24 V mode.
(Note 2)
The default value of input time constant is 2 µs.
Limitations on number of simultaneous input on points
(Note 1)
There is no limitation on the number of simultaneous on points in the ambient temperature range
between 0 to 55°C when using 12 V DC or 5 V DC.
● Use the input voltage within ±10% of 5 V, 12 V or 24 V. Heat or chattering may be
generated when using a voltage out of this range.
Internal circuit diagram and external connection diagram
R1 = 10 kΩ, R2a = 4.3 kΩ, R2b = 5.6 kΩ, R2c = 510 Ω
3-4
5 - 24 V mode
1.0 µs or less (at 5 V DC)
2.0 µs or less (at 12 V DC)
3.5 µs or less (at 24 V DC)
1.0 µs (at 5 V/12 V DC)
2.0 µs (at 24 V DC)
0, 0.5 μs/1 μs/1.5 μs/2 μs/4 μs/8 μs/16 μs/32 μs/64 μs/96 μs/128 μs/256 μs/
(Note 2)
2 ms/4 ms/8 ms
4 points/1 common (±common)
Specifications
12 - 24 V mode