Example 1 of using sink and source outputs
Example 2 of using sink and source outputs
(Note 1)
When the polarities are mixed, a warning occurs and the ERR LED on the unit flashes to remind
users to check the wiring.
To disable warning announcement, set "Warning annunciation" to ""Not announce"" in the ""Multi
I/O Unit Setting"" screen of tool software FPWIN GR7. (Available since Ver.1.1.) Or, set bit 9 of
UM00062 to 1.
5.2.2 Allocation of Contacts to Output Terminals
The contact allocation function to output terminals is a function to allocate Y contacts to output
terminals by four points. The arrangement can be changed from the initial state and the same Y
contact can be allocated to multiple terminals.
■
Example of contact allocation
In this example, "Output terminal polarity" is set to use sink and source outputs and the signals
of A15-A18 are replaced with the signals of B11-B14.
WUME-FP7MXY-06
5.2 Output Terminal Setting