9.1 Pulse Output / PWM Output Function

9.1.4 Configuration Using Tool Software

The setting of the pulse output/PWM output function is specified in the configuration menu of
FPWIN GR7.
Setting method
The following procedure describes the process when the multi I/O unit has been already
allocated in the I/O map.
1.
Select Options>Multi I/O Unit Setting in the menu bar.
The ""Multi I/O Unit Setting"" dialog box is displayed. Select a unit to be used.
2.
From the function selection tree, select ""Pulse output"", and double-click an output number
to which the pulse output/PWM output is allocated.
The ""Pulse Output Advanced"" dialog box is displayed.
3.
Select a function setting, data update timing, and input a frequency.
When selecting PWM output, set a duty ratio. Set the upper and lower limit values of the
counter for the pulse output/PWM output according to applications.
4.
Select a pulse start logic.
Select either ""OFF start"" or ""ON start"".
5.
Press the [[OK]] button.
The selected condition will be registered in the ""Multi I/O Unit Setting"" dialog box.