5.1.3.2
Dimension drawing and drilling dimensions for the 400 V converter
Dimension drawing
All dimensions are specified in millimeters.
Table 5-2
Frame size
FSA
FSB
FSC
FSD
5.1.4
Minimum clearances
Description
Observe the following minimum mounting clearances. For converters without built-in fans,
install cooling fans above the converters for sufficient heat dissipation.
Note
For converters without built-in fans, when the surrounding temperature in the cabinet is ≥ 45 °C
(for 200 V FSA: ≥ 40 °C), the airflow velocity above the converters must be greater than
0.5 m/s.
All dimensions are specified in millimeters.
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA
Dimensions and mounting, 3 AC 400 V, FSA ... FSD, IP20
Width
50 mm
60 mm
70 mm
95 mm
Height
Depth
180 mm
200 mm
180 mm
200 mm
180 mm
200 mm
260 mm
230 mm
Mounting
5.1 Converter
Fixing
2 x M4 / 2.5 Nm
4 x M4 / 2.5 Nm
97