Sets the input terminal to connect probe 2.
Value:
0:
 
211:
Index:
[0] = Motor encoder
[1] = Reserved
[2] = Reserved
Dependency:
See also: p0488, p0490
CAUTION
In order to prevent incorrect measurement values, these parameters may not be written during an active measurement.
Note
DI: Digital Input
If parameterization is rejected, check whether the terminal is already being used in p2517 or p2518.
p0490.0...1
Invert measuring probe or equivalent zero mark
S200 PTI
Data type: Unsigned32
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
 
Unit: -
 
Min:
-
Description:
Setting to invert the digital input signals to connect a measuring probe or an equivalent zero mark.
Bit array:
Bit
 
00
 
01
Dependency:
See also: p0488, p0489, p0494
Note
The terminal must be set as input.
When the measuring probe or the equivalent zero mark is inverted, this has no effect on the status displays of the digital
inputs (r0721, r0722).
DI: Digital Input
p0494[0]
Equivalent zero mark input terminal
S200 PTI
Data type: Integer16
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
 
Unit: -
 
Min:
0
Description:
Selects the input terminal for connecting an equivalent zero mark (external encoder zero mark).
Value:
0:
 
210:
 
211:
Dependency:
See also: p0490
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA
No measuring probe
DI 1 (X132.6)
Signal name
DI 0 (X132.5)
DI 1 (X132.6)
No equivalent zero mark (evaluation of the encoder zero mark)
DI 0 (X132.5)
DI 1 (X132.6)
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Operation
Measuring probe
Max:
-
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Operation
Motor encoder, Homing
Max:
211
A.3 Parameters
 
Factory setting:
0000 bin
1 signal
0 signal
Inverted
Not inverted
Inverted
Not inverted
 
Factory setting:
0