For more information about wiring analog inputs, see Section "Connecting the inputs and
outputs (Page 147)".
Parameters
The following list includes the parameters of the "Analog inputs" function.
Number
r0755[0...1]
p0756[0...1]
p0757[0...1]
p0758[0...1]
p0759[0...1]
p0760[0...1]
p0768[0...1]
9.3.4

Analog outputs

Overview
An analog output can output a voltage signal. Based on an adjustable characteristic, the S200
PTI converter converts an internal percentage value into a voltage signal. A signal
interconnection defines the function of the analog output.
Description of function
The S200 PTI converter has two analog outputs, AO0 and AO1. The parameter c0771[x] is
assigned to the two analog outputs. You can adjust the function of the analog outputs in
commissioning tools.
The following signals are assignable to the analog outputs.
Parame‐
ter
r0063
r0080
r0062
r0079
r0070
r29350
r29351
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA
Name
Analog inputs, actual value in percent
Analog inputs type
Analog inputs characteristic value x1
Analog inputs characteristic value y1
Analog inputs characteristic value x2
Analog inputs characteristic value y2
Analog inputs noise suppression window
Signal
Actual speed smoothed
Torque actual value
Speed setpoint after the filter
Torque setpoint
Actual DC link voltage
Pulse input frequency
Remaining number of pulses
Functions
9.3 Inputs/outputs
Unit
[%]
 
 
[%]
 
[%]
[%]
Available control mode
Fast PTI S
T
-
-
-
-
235