Appendix
A.3 Parameters
p1130[0]
Ramp-function generator initial rounding-off time
S200 PTI
Data type: FloatingPoint32
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
Unit: s
Min:
0.000 [s]
Description:
Sets the initial rounding-off time for the extended ramp-function generator.
The value applies to ramp-up and ramp-down.
Note
Rounding-off times avoid an abrupt response and prevent damage to the mechanical system.
p1131[0]
Ramp-function generator final rounding-off time
S200 PTI
Data type: FloatingPoint32
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
Unit: s
Min:
0.000 [s]
Description:
Sets the final rounding-off time for the extended ramp generator.
The value applies to ramp-up and ramp-down.
Note
Rounding-off times avoid an abrupt response and prevent damage to the mechanical system.
p1135[0]
OFF3 ramp-down time
Data type: FloatingPoint32
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
Unit: s
Min:
0.000 [s]
Description:
Sets the ramp-down time from the maximum speed down to zero speed for the OFF3 command.
Note
This time can be exceeded if the DC link voltage reaches its maximum value.
646
Visible in: Extended display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Operation
Ramp-function generator
Max:
30.000 [s]
Visible in: Extended display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Operation
Ramp-function generator
Max:
30.000 [s]
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Operation
Ramp-function generator, Shutdown functions, Setpoint addition, Quick
commissioning
Max:
600.000 [s]
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA
Factory setting:
0.000 [s]
Factory setting:
0.000 [s]
Factory setting:
0.000 [s]