System messages
11.3 Faults and alarms
Remedy:
Correct parameters:
For xxxx = 10006 or 10022:
- Set a valid signal source in pxxxx.
C01682
SI: Monitoring function not supported
Message class:
Error in the parameterization / configuration / commissioning procedure (18)
Message value:
%1
Variant:
S200 PTI
Component:
None
Response:
OFF2
Acknowledgment: IMMEDIATELY
Cause:
At least one of the monitoring functions enabled in p9604 is not supported with this firmware version on this device.
Note:
The message value (r60049, interpret binary) indicates the bits of the monitoring functions, which form this firmware
version on this device, are not supported. If several, non-supported monitoring functions are simultaneously enabled, then
these are all displayed in the message value.
This message results in an STO (Safe Torque Off).
See also: p9604 (SI enable)
Remedy:
Correct parameter p9604 so that monitoring functions only permitted for this firmware version and for this device are
enabled.
See also: p9604 (SI enable)
C01690
SI: Data backup problem for the NVRAM
Message class:
Hardware/software error (1)
Message value:
%1
Variant:
S200 PTI
Component:
Control Unit (CU)
Response:
OFF2
Acknowledgment: POWER ON
Cause:
When saving parameters r9780, r9781 and r9782 (Safety logbook) says, an error has occurred in conjunction with the
NVRAM.
Note:
This fault does not result in a safety stop response.
Fault value (r60049, interpret decimal):
1: There is no physical NVRAM in the drive.
2: There is no longer any free memory space in the NVRAM.
Remedy:
For fault value = 1:
- Replace the hardware.
For fault value = 2:
- De-select functions that are not required and that take up memory space in the NVRAM.
- Contact Technical Support.
Note:
NVRAM: Non-Volatile Random Access Memory (non-volatile read and write memory)
C01700
SI: STO (Safe Torque Off) initiated
Message class:
Safety monitoring channel has identified an error (10)
Message value:
-
Variant:
S200 PTI
Component:
None
Response:
OFF2