3. Arrange and cut the conductors.
The conductor length required for termination into the hybrid plug varies depending on the
variant of the hybrid plug and the contacts. Conductors that are close to the cable outlet
should be cut 3 mm more.
The following images show the conductor length requirement of the drive-end hybrid plug.
4. Strip the power and PE conductors by 2.4 mm ± 0.5 mm, and encoder and brake conductors
by 2.2 mm ± 0.5 mm.
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA
Conductor
Power conductor U
Power conductor V
Power conductor W
PE conductor
Brake conductor +
Brake conductor -
Signal conductors A, B, and C
Signal conductors D, E, and F
Conductor length requirement (mm)
Drive-end variant
25 ± 1
22 ± 1
25 ± 1
22 ± 1
25 ± 1
25 ± 1
22 ± 1
25 ± 1
Appendix
A.4 Assembling cables
Non-drive end variant
22 ± 1
25 ± 1
22 ± 1
25 ± 1
25 ± 1
25 ± 1
25 ± 1
22 ± 1
743