Holding Brake (Option); Dimension Drawings - Siemens 1FT6031-4AK71-4AH0-Z Manual

Servo motors
Table of Contents

Advertisement

Motor Components (Options)

4.5 Holding brake (option)

4.5
Holding brake (option)
For a description of the function, refer to the Configuration Manual "General Section for
Synchronous Motors".
The holding brake cannot be retrofitted! Motors with holding brake are longer by the mounted
space required (refer to the dimension drawing).
Table 4-12
Technical data of the holding brakes used for 1FT6 motors
Motor type
Brake type
1FT602⃞
EBD 0.11 B
1FT603⃞
EBD 0.15 B
1FT604⃞
EBD 0.4 BA
1FT606⃞
EBD 1.5 B
1FT6081
EBD 1.2 B
1FT6082
EBD 1.2 B
1FT6084
EBD 3.5 BN
1FT6086
EBD 3.5 BN
1FT610⃞
EBD 4 B
1FT613⃞
EBD 8 B
2)
Standardized acc. to VDE 0580 with varistor circuitry
1)
not for water cooling
2)
Holding torque M
4
The holding torque M
motor is at a standstill).
4-12
Holding torque
Direct current
M4
1)
[Nm]
[A]
1
0.3
2
0.4
5
0.8
15
0.8
15
0.8
15
0.8
28
0.9
28
0.9
70
1.4
140
1.7
is the minimum brake torque in steady-state operation (when the
4
Configuration Manual, (PFT6), Edition 12.2004, 6SN1197-0AD12-0BP0
Opening time
Closing time
with varistor
with varistor
[ms]
[ms]
20
10
30
15
50
20
130
30
150
35
150
35
180
35
180
35
220
50
300
90
1FT6 synchronous motors
Highest
switching
energy
[J]
9
27
125
320
750
750
1600
1600
2100
9800