Cause:
- A trigger signal was not specified.
- The specified signal does not exist.
- The specified signal is not a fixed-point signal.
- The specified signal cannot be used as a trigger signal for the trace.
Remedy:
Specify a valid trigger signal.
A02063
Trace: Invalid data type
Message class:
Error in the parameterization / configuration / commissioning procedure (18)
Message value:
%1
Component:
None
Response:
NONE
Acknowledgment: NONE
Cause:
The specified data type to select a signal using a physical address is invalid.
Remedy:
Use a valid data type.
A02070
Trace: Parameter cannot be changed
Message class:
Error in the parameterization / configuration / commissioning procedure (18)
Message value:
-
Component:
None
Response:
NONE
Acknowledgment: NONE
Cause:
The trace parameter settings cannot be changed when the trace is active.
Remedy:
- Stop the trace before parameterization.
- If required, start the trace.
A02075
Trace: Pretrigger time too long
Message class:
Error in the parameterization / configuration / commissioning procedure (18)
Message value:
-
Component:
None
Response:
NONE
Acknowledgment: NONE
Cause:
The selected pretrigger time must be shorter than the trace time.
Remedy:
Check the pretrigger time setting and change if necessary.
F02080
Trace: Parameterization deleted due to unit changeover
Message class:
Error in the parameterization / configuration / commissioning procedure (18)
Message value:
-
Component:
None
Response:
NONE
Acknowledgment: IMMEDIATELY
Cause:
The trace parameterization in the drive unit was deleted due to a unit changeover or a change in the reference parameters.
Remedy:
Restart trace.
A02085
Message function: Parameterization error
Message class:
Error in the parameterization / configuration / commissioning procedure (18)
Message value:
Parameter: %1, index:%2
Component:
Power Unit
Response:
NONE
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA
System messages
11.3 Faults and alarms
389