Siemens SINAMICS S200 Operating Instructions Manual page 646

Pulse train servo drive system
Hide thumbs Also See for SINAMICS S200:
Table of Contents

Advertisement

Appendix
A.3 Parameters
Dependency:
Selects the required fixed speed setpoint using c1020 ... c1023.
Displays the number of the actual fixed speed setpoint in r1197.
Sets the values for the fixed speed setpoints 1 ... 15 using p1001 ... p1015.
See also: c1020, c1021
Note
If a fixed speed setpoint has not been selected (c1020 ... c1023 = 0, r1197 = 0), then r1024 = 0 (setpoint = 0).
p1082[0]
Maximum speed
 
Data type: FloatingPoint32
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
 
Unit: rpm
 
Min:
0.000 [rpm]
Description:
Sets the maximum motor speed to a value less than or equal to the maximum motor speed (p0322).
The set value is valid for both directions of rotation.
Dependency:
See also: p0322
p1083[0]
Speed limit in positive direction of rotation
 
Data type: FloatingPoint32
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
 
Unit: rpm
 
Min:
0.000 [rpm]
Description:
Sets the maximum speed for the positive direction.
p1086[0]
Speed limit in negative direction of rotation
 
Data type: FloatingPoint32
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
 
Unit: rpm
 
Min:
-210000.000 [rpm]
Description:
Sets the speed limit for the negative direction.
644
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Ready for operation
Motorized potentiometer, Speed limiting, U/f control, Speed controller, Quick
commissioning
Max:
210000.000 [rpm]
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Operation
Speed limiting, U/f control, Speed controller
Max:
210000.000 [rpm]
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Operation
Speed limiting, U/f control, Speed controller
Max:
0.000 [rpm]
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA
 
Factory setting:
1500.000 [rpm]
 
Factory setting:
210000.000 [rpm]
 
Factory setting:
-210000.000 [rpm]

Advertisement

Table of Contents
loading