Appendix
A.3 Parameters
• c...
• p0972
• p0489[0...2]
• r0945
• r0196[0...255].0...15 Display parameter with index 0 to 255 and bit array from bit 0 to bit
• r5613.0...1
• c8997[0...2]
Other examples of the notation in the documentation:
• p9563[1]
• r0196[1].5
• r0964[2]
• p5611.1
Parameter name
Shows the parameter name in the long form.
Variant
Specifies the product variant for which the parameter is valid. This information is not
applicable if a parameter is the same for all product variants used in the parameter list.
Data type
Each parameter is assigned one of the following data types:
• Integer8
• Integer16
• Integer32
• Unsigned8
• Unsigned16
• Unsigned32
• FloatingPoint32 Float
Visible in
You change the number of parameters displayed in the commissioning tool via:
• Standard display
Only the basic parameters are displayed.
• Extended display
The full scope of parameters is displayed.
Permission
The user and rights management (UMAC) controls access to the parameters.
You require runtime function rights to read and set parameters.
The following read permissions are available:
• Read drive data or acknowledge messages
586
Display parameters (read-only)
Adjustable parameter 972
Adjustable parameter 489, index 0 to 2
Display parameter 945
15
Display parameter 5613 with bit array from bit 0 to bit 1
Display parameter 8997, index 0 to 2
Adjustable parameter 9563, index 1
Display parameter 196, index 1, bit 5
Display parameter 964, index 2
Adjustable parameter 5611, bit 1
I8
8-bit integer
I16
16-bit integer
I32
32-bit integer
U8
8-bit without sign
U16
16-bit without sign
U32
32-bit without sign
32-bit floating-point number