p0760[0...1]
Analog inputs characteristic value y2
S200 PTI
Data type: FloatingPoint32
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
 
Unit: %
 
Min:
-1000.00 [%]
Description:
Sets the scaling characteristic for the analog inputs.
The scaling characteristic for the analog inputs is defined using 2 points.
This parameter specifies the y coordinate (percentage) of the 2nd value pair of the characteristic.
Index:
[0] = AI0 (X132.19/20)
[1] = AI1 (X132.21/22)
Note
The parameters for the characteristic do not have a limiting effect.
p0761[0...1]
Analog inputs wire break monitoring, response threshold
S200 PTI
Data type: FloatingPoint32
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
 
Unit: -
 
Min:
0.00
Description:
Sets the response threshold for the wire breakage monitoring of the analog inputs.
Index:
[0] = AI0 (X132.19/20)
[1] = AI1 (X132.21/22)
Dependency:
For the following analog input type, the wire breakage monitoring is active:
p0756[0...1] = 1 (monitored unipolar voltage input (+2 V ... +10 V)), unit [V].
See also: p0756
Note
AI: Analog Input
p0762[0...1]
Analog inputs wire-break monitoring delay time
S200 PTI
Data type: Unsigned16
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
 
Unit: ms
 
Min:
0 [ms]
Description:
Sets the delay time for the wire breakage monitoring of the analog inputs.
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Operation
Analog inputs
Max:
1000.00 [%]
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Operation
Analog inputs
Max:
10.00
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Operation
Analog inputs
Max:
1000 [ms]
A.3 Parameters
 
Factory setting:
100.00 [%]
 
Factory setting:
2.00
 
Factory setting:
100 [ms]
Appendix
623