Note
Additional explanations about parameters
A.3.2
Parameter list
Product: SINAMICS S200, Version: 603021000, Language: eng
Objects: S200 Basic PTI, S200 PTI
r0002
Drive operating display
Data type: Integer16
Read permission:
Write permission:
Parameter group:
Unit: -
Description:
Operating display for the drive.
Value:
0:
10:
11:
12:
13:
14:
15:
16:
17:
18:
21:
22:
23:
31:
35:
41:
42:
43:
44:
45:
46:
60:
70:
200:
250:
Dependency:
See also: r0046
NOTICE
For several missing enable signals, the corresponding value with the highest number is displayed.
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Status parameters, Diagnostics general, Drive enable signals
Operation - Everything enabled
Operation - Set "Enable setpoint" = "1"
Operation - Set "Enable speed controller" = "1"
Operation - RFG frozen, set "RFG start" = "1"
Operation - Set "Enable ramp-function generator" = "1"
Operation - MotID, excitation running or brake opens, SS2
Operation - Open brake (p1215)
Operation - Withdraw braking with OFF1 using "ON/OFF1" = "1"
Operation - Braking with OFF3 can only be interrupted with OFF2
Operation - Brake on fault, remove fault, acknowledge
Ready for operation - Set "Enable operation" = "1"
Ready for operation - De-magnetizing running
Ready for operation - Set "Infeed operation" = "1"
Ready for switching on - Set "ON/OFF1" = "0/1"
Switching on inhibited - Carry out first commissioning
Switching on inhibited - Set "ON/OFF1" = "0"
Switching on inhibited - Set "Operating condition/OFF2" = "1"
Switching on inhibited - Set "Operating condition/OFF3" = "1"
Switching on inhibited - Supply STO terminal w/ 24 V (hardware)
Switching on inhibited - Rectify fault, acknowledge fault, STO
Switching on inhibited - Exit commissioning mode
Drive deactivated/not operational
Initialization
Wait for run-up/partial run-up
Device signals a topology error
A.3 Parameters
Appendix
589