Siemens SINAMICS S200 Operating Instructions Manual page 390

Pulse train servo drive system
Hide thumbs Also See for SINAMICS S200:
Table of Contents

Advertisement

System messages
11.3 Faults and alarms
A02056
Trace: Recording cycle too short
Message class:
Error in the parameterization / configuration / commissioning procedure (18)
Message value:
-
Component:
None
Response:
NONE
Acknowledgment: NONE
Cause:
The selected recording clock cycle is shorter than the selected basic clock cycle 0.
Remedy:
Increase the value for the trace cycle. The fastest cycle time can be read out using the commissioning tool.
A02057
Trace: Time slice clock cycle invalid
Message class:
Error in the parameterization / configuration / commissioning procedure (18)
Message value:
-
Component:
None
Response:
NONE
Acknowledgment: NONE
Cause:
The time slice clock cycle selected does not match any of the existing time slices.
Remedy:
Enter an existing time slice clock cycle. The fastest cycle time can be read out using the commissioning tool.
A02059
Trace: Time slice clock cycle for 2 x 8 recording channels not valid
Message class:
Error in the parameterization / configuration / commissioning procedure (18)
Message value:
-
Component:
None
Response:
NONE
Acknowledgment: NONE
Cause:
The selected time slice clock cycle cannot be used for more than 4 recording channels.
Remedy:
Enter the clock cycle of an existing time slice with a cycle time >= 4 ms or reduce the number of recording channels to 4
per trace.
The fastest cycle time can be read out using the commissioning tool.
A02060
Trace: Signal to be traced missing
Message class:
Error in the parameterization / configuration / commissioning procedure (18)
Message value:
-
Component:
None
Response:
NONE
Acknowledgment: NONE
Cause:
- A signal to be traced was not specified.
- The specified signals are not valid.
Remedy:
- Specify the signal to be traced.
- Check whether the relevant signal can be traced.
A02062
Trace: Invalid trigger signal
Message class:
Error in the parameterization / configuration / commissioning procedure (18)
Message value:
-
Component:
None
Response:
NONE
Acknowledgment: NONE
388
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA