Corrective maintenance

12.1

Service and maintenance for the converter

12.1.1

Restoring the converter to factory settings

12.1.1.1

Restoring factory settings via a commissioning tool

Description
The restoring to factory settings with a commissioning tool (web server) only deletes the user-
specific parameterization of the converter, for example motor data.
The following settings are retained with the restoring:
• Activation and settings of User Management & Access Control
• The "IP configuration" and "Device name" communication settings of the service interface
(X127)
• Installed firmware on the converter
The restoring to factory settings with the commissioning tool is described in Section "Restore
factory settings (Page 209)".
12.1.1.2

Reset of all user-defined settings to the factory setting via an SD card

Overview
The following user-defined settings are stored in the converter:
• Parameterization of the converter
• Activation and settings of User Management & Access Control
• "IP configuration" and "Device name" communication settings of the service interface (X127)
• Self-generated certificates
• User-defined parameter lists in the web server
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2