Siemens SINAMICS S200 Operating Instructions Manual page 629

Pulse train servo drive system
Hide thumbs Also See for SINAMICS S200:
Table of Contents

Advertisement

Index:
[0] = AO0 (X132.45/46)
[1] = AO1 (X132.47/48)
Note
AO: Analog Output
r0774[0...1]
CU analog outputs output voltage/current actual
S200 PTI
Data type: FloatingPoint32
Read permission:
Write permission:
Parameter group:
Unit: V
Description:
Displays the actual output voltage at the analog outputs.
Index:
[0] = AO0 (X132.45/46)
[1] = AO1 (X132.47/48)
Dependency:
See also: p0776
Note
AO: Analog Output
p0775[0...1]
CU analog outputs activate absolute value generation
S200 PTI
Data type: Integer16
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
 
Unit: -
 
Min:
0
Description:
Activates the absolute value generation for the analog outputs.
Value:
0:
 
1:
Index:
[0] = AO0 (X132.45/46)
[1] = AO1 (X132.47/48)
Note
AO: Analog Output
p0776[0...1]
CU analog outputs type
S200 PTI
Data type: Integer16
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
 
Unit: -
 
Min:
1
Description:
Sets the analog output type.
p0776[x] = 1, 4 corresponds to a voltage output.
Value:
1:
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Analog outputs
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Ready for operation
Analog outputs
Max:
1
No absolute value generation
Absolute value generation switched in
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Operation
Analog outputs
Max:
4
Voltage output (0 V ... +10 V)
A.3 Parameters
 
 
Factory setting:
0
 
Factory setting:
1
Appendix
627