p1215[0]
Motor holding brake configuration
S200 Basic PTI
Data type: Integer16
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
 
Unit: -
 
Min:
0
Description:
Sets the configuration for the motor holding brake.
Value:
0:
 
3:
Dependency:
See also: p1216, p1217, p1226, p1227, p1228
CAUTION
For the setting p1215 = 0, if a brake is used, it remains closed. If the motor moves, this will destroy the brake.
NOTICE
If p1215 was set to 3, then when the pulses are canceled, the brake is closed even if the motor is still rotating. Pulses
can be canceled as a result of an OFF2 or "Enable operation" via fieldbus or a fault with OFF2 response.
Note
If an external motor holding brake is being used, then p1215 should be set to 3 and r0899.12 should be used as brake
control signal.
The parameter can only be set to zero when the pulses are inhibited.
p1215[0]
Motor holding brake configuration
S200 PTI
Data type: Integer16
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
 
Unit: -
 
Min:
0
Description:
Sets the configuration for the motor holding brake.
For value 2:
This setting allows the motor shaft to be rotated for installation purposes.
Value:
0:
 
1:
 
2:
Dependency:
See also: p1216, p1217, p1226, p1227, p1228
CAUTION
For the setting p1215 = 0, if a brake is used, it remains closed. If the motor moves, this will destroy the brake.
Setting p1215 = 2 is not permissible if the brake is used to hold loads.
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Ready for operation
Motor holding brake
Max:
3
No motor holding brake available
Motor holding brake like seq control, conn via interconnection
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Ready for operation
Motor holding brake
Max:
2
No motor holding brake available
Motor holding brake acc. to sequence control
Motor holding brake always open
A.3 Parameters
 
Factory setting:
0
 
Factory setting:
0
Appendix
647