Siemens SINAMICS S200 Operating Instructions Manual page 507

Pulse train servo drive system
Hide thumbs Also See for SINAMICS S200:
Table of Contents

Advertisement

Parameter
Degree of protection according to
IEC 60529
Mains supply
Permissible mains supply network
Line voltage
Line frequency (Hz)
Permissible line voltage fluctuation
Permissible line frequency fluctua‐
tion
24 V DC power supply
Voltage (V)
Permissible voltage fluctuation (V)
Maximum current (A)
Safety insulation class
Speed control mode
Speed control range
Analog speed command input
Torque limit
Position control mode
Maximum input pulse frequency
Command pulse multiplying factor
In-position range setting
Error excessive
Torque limit
Torque control mode
Analog torque command input
Speed limit
Inputs and outputs
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA
Description
IP20
TN, TT, IT
1 AC/3 AC 200 V ... 240 V
3 AC 380 V ... 480 V
50/60
-15% ... +10%
-10% ... +10%
24 (-15% ... +20%)
6)
When using a motor without brake: 20.4 ... 28.8
When using a motor with brake: 22.8 ... 28.8
For 200 V variants:
– When using a motor without a brake: 1.2
– When using a motor with a brake: 2.2
For 400 V variants:
– When using a motor without a brake: 1.2
– When using a motor with a brake: 3.2
SELV
Analog speed command 1:2000, internal speed command 1:5000
-10 V DC to +10 V DC/rated speed
Set through a parameter or the analog input command (0 V DC to +10 V DC/maximum
torque)
4 M (differential input), 200 kpps (open collector input)
Recommended electronic gear ratio (A/B)
A: 1 - 10000, B: 1 - 10000
1/1000 < A/B < 64000
0 to 2147483647 pulse (command pulse unit)
±1/10 revolutions
Set through a parameter or the analog input command (0 V DC to +10 V DC/maximum
torque)
-10 V DC to +10 V DC/maximum torque (input impedance 10 kΩ to 12 kΩ)
Set through a parameter or the analog input command (0 V DC to +10 V DC/maximum
speed)
Technical data
13.1 Technical data of the converter
505

Advertisement

Table of Contents
loading

Table of Contents