Mounting
5.2 Motor
Procedure
Proceed as follows to mount the feather key into the key slot:
1. Install the feature key ("
key slot are fitted closely. Siemens recommends that you place the V-type block ("
the shaft extension for supporting.
2. Knock the feather key into the key slot by using a copper bar.
Figure 5-4
5.2.8

Attaching output elements

Overview
Appropriate arrangement of the output elements reduces the bending torque load applied to
the shaft and the bearing.
114
Well‑lubricated feather key
Key slot
V-type block
Mounting the feather key
") to the key slot ("
") and make sure that the feather key and the
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA
") under