Gas flow sensor (in R500 Wire
Feeder EUR+ only)
- Gas flow error
- Sensing level
- Gas type
- Sensor start time
Watchdog

3.2.13 Fieldbus settings

Fieldbus settings can be accessed via the Settings view menu in AX Manager. The tables below list the setting para-
meters for each supported fieldbus. The fieldbus settings view varies according to the fieldbus module used.
© Kemppi
OFF/ON
Gas flow sensor is used to measure the shielding gas flow rate.
Default = OFF
When the gas flow sensor is set to OFF, the gas flow status is
OK.
When the gas flow sensor is set to ON, the measured values are
shown in the Home, Tools and Robot status views during weld-
ing.
OFF/ON
When set to OFF, the welding system does not give an error
Default = OFF
even if the gas flow rate is below the sensing level.
When set to ON, and the gas flow rate is below sensing level,
the welding system gives an error and welding stops.
5.0 l/min ... 20.0 L/min
If the gas flow is below the sensing level and the gas flow error
Default = 10.0 L/min
is set to ON, the welding system gives an error and welding
stops.
CO2 / Argon /
The gas type used for welding.
Ar+8%CO2 /
Ar+18%CO2
Default = Ar+18%CO2
0.1 s ... 5.0 s
Gas sensor start time when the gas flow sensor is ON.
Default = 3.0 s
OFF/ON
When watchdog is enabled, the robot must toggle the watch-
Default = OFF
dog bit periodically. If the robot stops toggling the watchdog
bit, the welding system gives an error and welding stops.
127
AX MIG Welder
Operating manual - EN
1921900 / 2318