Kemppi 6: A7 Mig Welder Weldeye Compatibility Fieldbus Control Table - Kemppi AX MIG Welder Operating Manual

Table of Contents

Advertisement

2.27.4 KEMPPI 6: A7 MIG Welder WeldEye compatibility fieldbus control table

Interface number: 17
Table size: 49 bytes
Control parameters (from robot to welding system)
Byte
0
1
2
3
4
5
6
7
8
9
10
© Kemppi
Bit/Type
UINT16
UINT16
UINT8
UINT8
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
-
-
Control parameter
(Not in use)
(Not in use)
MemoryChannel
(Not in use)
StartWelding
SimulationMode
WireInchForward
WireInchBackward
GasBlow
AirBlow
TouchSensorToolSel
TouchSensorOn
(Not in use)
ErrorReset
(Not in use)
Watchdog
(Not in use)
(Not in use)
(Not in use)
(Not in use)
DigitalOutput1
DigitalOutput2
DigitalOutput3
DigitalOutput4
DigitalOutput5
DigitalOutput6
DigitalOutput7
DigitalOutput8
(Not in use)
(Not in use)
80
AX MIG Welder
Operating manual - EN
1921900 / 2318

Advertisement

Table of Contents
loading

Table of Contents