3.2.3 Settings

The contents of the Settings menu depend on the welding process, current mode and welding mode selected.
To select and adjust parameters in Settings menu:
1.
Press the parameter settings button (10) to enter the menu.
2.
Browse through the menu parameters by turning the control knob (1).
3.
Select a parameter for adjustment by pressing the control knob button (1).
4.
Adjust the selected parameter by turning the control knob (1).
5.
Close the parameter setting by pressing the control knob button (1).
To enter advanced Settings menu:
Press the Settings button (10) for 5 seconds.
Rarely used settings items are hidden by default. Those are available in the advanced settings menu.
Settings:
Latest weld: Current, voltage, arc time
>> This settings item shows last weld data values.
AC Waveform: Sine / Optima / Square (Default: Optima)
Spot time: 0.1 s ... 150.0 s, step 0.1 / 1.0 s (Default = 2.0 s)
MIX TIG AC ratio: 10 % ... 90 %, step 1 % (Default = 50 %)
MIX TIG cycle time: 0.1 s ... 1.0 s, step 0.1 s (Default = 0.6 s)
MIX TIG DC level: 50 % ... 150 %, step 1 % (Default = 100 %)
MicroTack spot time: 1 ms ... 200 ms, step 1 ms (Default = 10 ms)
MicroTack pause time: 50 ms ... 500 ms, step 1 ms (Default = 50 ms)