Settings - Kemppi MasterTig 235ACDC Operating Manual

Hide thumbs Also See for MasterTig 235ACDC:
Table of Contents

Advertisement

* Auto Pulse mode has different parameter values and they cannot be adjusted.
"Welding processes and features" on page 72

3.2.3 Settings

The contents of the Settings menu depend on the welding process, current mode and welding mode selected.
To select and adjust parameters in Settings menu:
1.
Press the parameter settings button (10) to enter the menu.
2.
Browse through the menu parameters by turning the control knob (1).
3.
Select a parameter for adjustment by pressing the control knob button (1).
4.
Adjust the selected parameter by turning the control knob (1).
5.
Close the parameter setting by pressing the control knob button (1).
To enter advanced Settings menu:
Press the Settings button (10) for 5 seconds.
Rarely used settings items are hidden by default. Those are available in the advanced settings menu.
Settings:
Parameter
Latest weld
AC Waveform
Spot time
© Kemppi
Value
Current, voltage, arc time
Sine / Optima / Square (Default: Optima)
0.1 s ... 150.0 s, step 0.1 / 1.0 s (Default = 2.0 s)
MasterTig 235ACDC, 325DC, 335ACDC, 425DC
Note
This settings item shows last weld data values.
32
Operating manual - EN
1920900 / 2052

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mastertig 325dcMastertig 335acdcMastertig 425dcMastertig cooler mMastertig 235acdc gmMastertig 325dc g ... Show all

Table of Contents