Pulse / DPulse / MAX Position welding parameters (MasterMig 355 only)
The parameters listed here are available for adjustment with the pulse and MAX Position welding processes in addition to the
MIG and 1-MIG welding parameters. For more information on the processes, refer to "Additional guidance to functions and fea-
tures" on page 45.
Parameter
Pulse current
- Level
DPulse
- Frequency
- Pulse ratio
MAX Position
- Frequency

3.3.7 Control panel: System settings

Changing settings
1.
Turn the right control knob to highlight the desired settings parameter.
2.
Press the right control knob to select the settings parameter for adjustment.
3.
Turn the right control knob to select the settings value.
>> Depending on the settings parameter to be adjusted, refer also to the Settings table below for more details.
4.
Confirm the new value / selection by pressing the right control knob.
Settings
Parameter
Remote control
Remote selection
Remote mode
© Kemppi
Parameter value
-10 ... 15 %
Default = 0 %
0.4 ... 8.0 Hz
Default = 2 Hz
10 ... 90 %
Default = 35 %
-0.5 ... 0.5 Hz
Default = 0 Hz
Parameter value
ON/OFF
Default = OFF
Hand remote / Gun remote
Default = Hand remote
Wire feed speed / Channel
Default = Wire feed speed
42
Operating manual- EN
Description
The pulse current relative to the base cur-
rent in pulse and double pulse welding.
This adjusts the double pulse frequency
and time percentage.
The pulse ratio adjusts the first pulse
level. When the pulse ratio is set at 35 %,
the ratio of the second pulse level is 65 %.
Note : The wire feed speed and voltage
fine tuning are adjusted in the main view.
This adjusts the MAX Position frequency.
Description
Select whether remote is used.
This determines what is changed with
the remote, wire feed speed or memory
channel (available channels: 1...5).